DARWIN-S184IB280004M
OVERVIEW
The DARWIN-S184IB280004M is a full gigabit managed industrial Ethernet fiber switch independently developed. It has 24*10/100/1000Base-T RJ45 ports and 4*100/1000Base-X SFP fiber slot ports (including 2 set combo ports). Each port can support wire-speed forwarding.
The DARWIN-S184IB280004M has L2+ full network management function, supports IPV4/IPV6 management, static route full line rate forwarding, complete security protection mechanism, complete ACL/QoS policy and rich VLAN functions, and is easy to manage and maintain. Supports multiple network redundancy protocols STP/RSTP/MSTP (<50ms) and (ITU-T G.8032) ERPS (<20ms) to improve link backup and network reliability. When one-way network fails, communication can be quickly restored to ensure important Uninterrupted communication for applications. According to the actual application requirements, you can configure multiple application services such as port traffic control, VLAN division, and SNMP through the Web network management mode. It meets the needs of various industrial Ethernet application environments and is suitable for industrial, intelligent transportation, rail transit, power industry, mining, petroleum, marine, metallurgical and green energy construction to form a cost-effective, stable and reliable communication network.
FEATURE
Gigabit access, Gigabit combo port uplink
◇ A combination of Gigabit Ethernet port and Gigabit SFP port to meet the networking requirements of various scenarios.
◇ Support non-blocking wire-speed forwarding.
◇ Support full-duplex based on IEEE802.3x and half-duplex based on backpressure.
Strong business processing capability
◇ IEEE802.1Q VLAN, flexible VLAN division, Voice VLAN, and QinQ configuration.
◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including EQU, SP, WRR & SP+WRR.
◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.
◇ IGMP V1/V2 and IGMP Snooping.
◇ ERPS/STP/RSTP/MSTP.
◇ Static and dynamic aggregation.
Security
◇ 802.1X authentication.
◇ Port isolation,Storm control.
◇ IP-MAC-VLAN-Port binding.
Stable and reliable
◇ Low power consumption, No fan, aluminum shell.
◇ Self-developed power supply, high redundancy design, providing a long term and stable PoE power output.
◇ CCC,CE, FCC, RoHS.
◇ The user-friendly panel, it can show the device status through the LED indicator of PWR, Link , L/A, SPEED.
DIMENSION
Interface Characteristics | |
Fixed Port | 24*10/100/1000Base-T RJ45 ports (Data) |
4*100/1000Base-X uplink SFP slot ports(Data) | |
1 * RS232 console port(115200,N,8,1) | |
1*AC100-240V power input port | |
2*DC12-48V power input port (support anti-reverse) | |
Alarm switch (FAULT) | |
Ethernet Port | Port 1-24 support 10/100/1000Base-T(X),Auto-sensing,Full/half duplex MDI/MDI-X self-adaption |
Twisted Pair Transmission | 10BASE-T: Cat3,4,5 UTP(≤100 meter) |
100BASE-TX: Cat5 or later UTP(≤100 meter) | |
1000BASE-T: Cat5e or later UTP(≤100 meter) | |
SFP Slot Port | Gigabit SFP optical fiber interface, default matching optical modules (optional order single-mode / multi-mode, single fiber / dual fiber optical module. LC) |
Optical Cable | Multi mode: 850nm 0 ~ 500M,single mode: 1310nm 0 ~ 40KM, 1550nm/0 ~ 120KM. |
SFP Port Expansion | Turbo overclocking 2.5G optical module and ring |
Chip Parameter | |
Network Management Type | L2+ |
Network Protocol | IEEE802.3 10BASE-T; IEEE802.3i 10Base-T; |
IEEE802.3u 100Base-TX; | |
IEEE802.3ab 1000Base-T | |
IEEE802.3z 1000Base-X | |
IEEE802.3x | |
Forwarding Mode | Store and Forward(Full Wire Speed) |
Switching Capacity | 256Gbps |
Forwarding | 38.69Mpps |
Rate@64byte | |
MAC | 8K |
Buffer Memory | 8M |
Jumbo Frame | 9.6K |
LED Indicator | Power:PWR(yellow), system :SYS(yellow), network ;Link/Act(yellow), Rate: SPEED: (green),Fiber port: L/A(green) |
Reset Switch | Yes, One-button factory reset |
Power | |
Total PWR / Input Voltage | 60W (AC100-240V) |
Power Consumption | Standby:<18W;Full load:<35W |
Power Supply | Built-in power supply, AC100~240V 50-60Hz 0.56A |
Power Input Interface | Dual power input interface, AC power supply priority, |
support anti-reverse protection, power-off automatic switching DC connection; 2 set DC12-48V input interface; Alarm switch ; 1 set AC power input interface | |
Physical Parameter | |
Operation TEMP / Humidity | -40~+80°C;5%~90% RH Non condensing |
Storage TEMP / Humidity | -40~+85°C;5%~95% RH Non condensing |
Dimension (L*W*H) | 440*298*44mm |
Net /Gross Weight | <4.7kg / <5.4kg |
Installation | Desktop, 19 inch 1U cabinet |
Certification & Warranty | |
Port lightning protection / protection level | Lightning protection: 6KV 8/20us;Protection level: IP40 |
IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge | |
IEC61000-4-3(RS):10V/m(80~1000MHz) | |
IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV | |
IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV | |
IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz) | |
IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s | |
IEC61000-4-9(pulsed magnet field):1000A/m | |
IEC61000-4-10(damped oscillation):30A/m 1MHz | |
IEC61000-4-12/18(shockwave):CM 2.5kV,DM 1kV | |
IEC61000-4-16(common-mode transmission):30V; 300V,1s | |
FCC Part 15/CISPR22(EN55022):Class A | |
IEC61000-6-2(Common Industrial Standard) | |
Mechanical Properties | IEC60068-2-6 (anti vibration) |
IEC60068-2-27 (anti shock) | |
IEC60068-2-32 (free fall) | |
Certification | CCC;CE mark, commercial; CE/LVD EN60950;FCC Part 15 Class B; RoHS; |
Warranty | 5 years, lifelong maintenance. |
Network Management Features | |
Interface | IEEE802.3X (Full-duplex) |
Broadcast storm control based on port speed | |
The speed limit of the message flow in the access port. The minimum particle size is 64Kbps. | |
Port temperature protection setting | |
Port green Ethernet Energy-saving setting | |
Layer 3 Features | L2+ Network management |
IPV4/IPV6 management | |
L3 soft routing forwarding, | |
Static route, Default route @ 128 pcs, APR @ 1024 pcs | |
VLAN | 4K VLAN based on port, IEEE802.1q |
VLAN based on the protocol | |
VLAN based on MAC | |
Voice VLAN, QinQ configuration | |
Port configuration of Access, Trunk, Hybrid | |
Port Aggregation | LACP, Static aggregation |
Max 13 aggregation groups and 8 ports per group. | |
Spanning Tree | STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s) |
Industrial Ring Network Protocol | G.8032 (ERPS),Recovery time less than 20ms |
255 Ring at most, Max 254 devices per ring. | |
Multicast | IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out |
MLD Snooping v1/v2,Multicast VLAN | |
Port Mirroring | Bidirectional data mirroring based on port |
QoS | Diff-Serv QoS,Priority Mark/Remark |
8*Output queues of each port | |
802.1p/DSCP priority mapping | |
Queue Scheduling Algorithm (SP, WRR, SP+WRR) | |
Flow-based Packet Filtering | |
Flow-based Redirection | |
Flow-based Rate Limiting | |
ACL | L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc. Port-based Issuing ACL. |
ACL based on port and VLAN | |
Security | User hierarchical management and password protection |
SSH 2.0,SSL,Port isolation,ARP message speed limit | |
Broadcast storm control,Backup for host datum | |
IEEE802.1X & MAC address authentication | |
Mac black holes,IP source protection | |
AAA & RADIUS,MAC learning limit | |
ARP inspection,Anti-DoS attack | |
IP-MAC-VLAN-Port binding | |
DHCP | DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay |
Management | Console/AUX Modem/Telnet/SSH2.0 CLI |
Web Management (HTTPS) | |
Download & Management on FTP, TFTP, Xmodem, SFTP,SNMP V1/V2C/V3 | |
One-key recovery | |
NTP,System work log,Ping Test | |
Cable Diagnose,LLDP | |
CPU instant utilization status view | |
ONV NMS - Smart Network Management System Platform (LLDP+SNMP) | |
System | Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later; |
Category 5 Ethernet network cable | |
TCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in a network |