Home / Industrial switches / DARWIN-S132ID241600M

DARWIN-S132ID241600M

(0)
  Sale 20%
Sale 20%
Buy now in 1 click
L2+ managed industrial PoE switch with 24* 10/100/1000M RJ45 ports. Port 1-16 can support IEEE802.3af/at PoE standard. It can support DC dual power supply input and DIN rail mounting.

OVERVIEW

 

 

The DARWIN-S132ID241600M series is a full gigabit L2+ managed industrial PoE switch independently developed. It has 24*10/100/1000Base-T RJ45 ports. Port 1-16 can support IEEE802.3af/at PoE standard. single port PoE power up to 30W. As a PoE power supply device, it can automatically detect and recognize the power receiving equipment that meets the standard and supply power through the network cable. It can supply power to POE terminal equipment such as wireless AP, web camera, VoIP phone, industrial sensor, visual intelligent building intercom through the network cable, and meet the network environment that needs high-density PoE power supply. It is suitable for industrial scenarios such as intelligent transportation, rail transit, power industry, mining, petroleum, shipping, metallurgy, and green energy construction to form a cost-effective, stable, and reliable network.

 

 

The DARWIN-S132ID241600M has L2+ network management function, support IPV4/IPV6 management, static route full line-rate forwarding, security protection mechanism, ACL/QoS policy and rich VLAN functions, and is easy to manage and maintain. Support multiple network redundancy protocols STP/RSTP/MSTP (<50ms) and (ITU-T G.8032) ERPS(<20ms) to improve link backup and network reliability. When the one-way network fails, communication can be quickly restored to ensure important Uninterrupted communication for applications. According to the actual application requirements, you can configure multiple application services such as port traffic control, VLAN division, and SNMP through the Web network management mode.

 

 

FEATURE

 

 

Full Gigabit access, wire-speed transmission

◇ Support line-speed full Gigabit Ethernet port, which facilitates flexible networking of users and meets networking requirements in various scenarios.

◇ Support non-blocking wire-speed forwarding.

◇ Support full-duplex based on IEEE802.3x and half-duplex based on backpressure.

 

 

Intelligent PoE power supply

◇ 16*10/100/1000Base-T RJ45 ports can support POE power supply to meet the needs of security monitoring, teleconferencing system, wireless coverage, and other scenarios.

◇ IEEE 802.3af/at PoE standard, without damaging non-PoE devices.

◇ Priority system for PoE port, it will supply power to the high priority level port first when the power budget is insufficient and avoid overwork of the device.

◇ PoE network management, realize PoE port power allocation, priority setting, port power status viewing, time scheduling, etc.

 

 

Security

◇ 802.1X authentication.

◇ Port isolation,Storm control.

◇ IP-MAC-VLAN-Port binding.

 

 

Strong business processing capability

◇ ERPS/STP/RSTP/MSTP.

◇ Static and dynamic aggregation.

◇ IGMP V1/V2 and IGMP Snooping.

◇ IEEE802.1Q VLAN, flexible VLAN division, Voice VLAN, and QinQ configuration.

◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including EQU, SP, WRR & SP+WRR.

◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.

 

 

Stable and reliable

◇ CCC,CE, FCC, RoHS.

◇ Low power consumption, no fan, aluminum shell.

◇ The user-friendly panel, it can show the device status through the LED indicator of PWR, SYS, Link, L/A, PoE.

◇ The DIN rail industrial switch series products do not have a power supply by default and need to be purchased. Users can purchase a power supply independently developed by ONV.

 

 

Easy operation and maintenance management

◇ HTTPS, SSLV3, and SSHV1/V2.

◇ RMON, system log, LLDP, and port traffic statistics.

◇ CPU monitoring, memory monitoring, Ping test, and cable diagnose.

◇ Web management, CLI command line (Console, Telnet), SNMP (V1/V2/V3).

 

 

DIMENSION

s132

Model DARWIN-S132ID241600M DARWIN-S132ID241600MW
Interface Characteristics    
Fixed Port 16*10/100/1000Base-T PoE ports (Data /Power)
  8*10/100/1000Base-T RJ45 ports(Data)  
  1*RS232 Console port (115200,N,8,1)  
  Power-off alarm switch (FAULT)  
  2 set of V+, V- redundant DC power interface (6 Pin Phoenix terminal)
Ethernet Port Port 1-24 support 10/100/1000Base-T,auto-sensing,Full/half duplex MDI/MDI-X self-adaption
Twisted Pair Transmission 10BASE-T: Cat3,4,5 UTP(≤100 meter)  
  100BASE-TX: Cat5 or later UTP(≤100 meter)
  1000BASE-T: Cat5e or later UTP(≤100 meter)
Chip Parameter    
Network Management Type L2+  
Network Protocol IEEE802.3 10BASE-T, IEEE802.3i 10Base-T
  IEEE802.3u 100Base-TX , IEEE802.3ab 1000Base-T
  IEEE802.3x  
Forwarding Mode Store and Forward(Full Wire Speed)  
Switching Capacity 256Gbps (Non-blocking)  
Forwarding 35.71Mpps  
Rate@64byte    
MAC 8K  
Buffer Memory 8M  
Jumbo Frame 9.6K  
LED Indicator Power: PWR(green), system: SYS(green), Network: Link (yellow), POE: PoE (green)
Reset Switch Yes, support one key to restore factory settings
PoE & Power    
PoE Port Port 1 to 16  
PoE Management PoE working status  
  Delay start of power supply  
  PoE output priority configuration  
  Scheduling of PoE operation and time  
  Total power limit of PoE power supply  
  PoE output power allocation, off& af &at  
Power Supply Pin Default: 1/2 (+), 3/6 (-)  
Max Power Per Port 30W, IEEE802.3af/at  
Total PWR / Input Voltage 240W/48VDC 400W/48VDC
Power Consumption Standby<10W, Full Load<240W Standby<12W, Full Load<400W
Power Input Interface 48-57VDC, 6 Pin industrial Phoenix terminal, support anti-reverse protection.
Power Supply No, optional 48V/240W or 48V/480W industrial power supply
Physical Parameter    
Operation TEMP / Humidity -40~+80°C;5%~90% RH Non condensing  
Storage TEMP / Humidity -40~+85°C;5%~95% RH Non condensing  
Dimension (L*W*H) 165*148*54mm  
Net /Gross Weight <2.2kg / <2.8kg  
Installation Desktop, DIN rail  
Certification & Warranty    
Lightning protection / protection level Port lightning protection: 6KV 8/20us; Protection level: IP40
  IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge
  IEC61000-4-3(RS):10V/m(80~1000MHz)  
  IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV
  IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV
  IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz)
  IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s
  IEC61000-4-9(pulsed magnet field):1000A/m
  IEC61000-4-10(damped oscillation):30A/m  1MHz
  IEC61000-4-12/18(shockwave):CM 2.5kV,DM 1kV
  IEC61000-4-16(common-mode transmission):30V; 300V,1s
  FCC Part 15/CISPR22(EN55022):Class A  
  IEC61000-6-2(Common Industrial Standard)  
Mechanical Properties IEC60068-2-6 (anti vibration)  
  IEC60068-2-27 (anti shock)  
  IEC60068-2-32 (free fall)  
Certification CCC;CE mark, commercial; CE/LVD EN60950;FCC Part 15 Class B; RoHS
Warranty 5 years, lifelong maintenance.  
Network Management Features    
Interface IEEE802.3X (Full-duplex)  
  Port temperature protection setting  
  Port green Ethernet Energy-saving setting  
  Broadcast storm control based on port speed
  The speed limit of the message flow in the access port.
  The minimum particle size is 64Kbps.  
Layer 3 Features L2+ network management ,IPV4/IPV6 management
  L3 soft routing forwarding,  
  Static route, Default route @ 128 pcs, APR @ 1024 pcs
VLAN 4K VLAN based on port, IEEE802.1q  
  VLAN based on the protocol  
  VLAN based on MAC  
  Voice VLAN, QinQ configuration  
  Port configuration of Access, Trunk, Hybrid  
Port Aggregation LACP, Static aggregation  
  Max 12 aggregation groups and 8 ports per group.
Spanning Tree STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s)
Industrial Ring Network Protocol G.8032 (ERPS),Recovery time less than 20ms
  250 Ring at most, Max 250 devices per ring.  
Multicast MLD Snooping v1/v2,Multicast VLAN  
  IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out
Port Mirroring Bidirectional data mirroring based on port  
QoS Flow-based Rate Limiting  
  Flow-based Packet Filtering  
  8*Output queues of each port  
  802.1p/DSCP priority mapping  
  Diff-Serv QoS,Priority Mark/Remark  
  Queue Scheduling Algorithm (SP, WRR, SP+WRR)
ACL Port-based Issuing ACL,ACL based on port and VLAN
  L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc.
Security IP-MAC-VLAN-Port binding  
  ARP inspection,Anti-DoS attack  
  AAA & RADIUS,MAC learning limit  
  Mac black holes,IP source protection  
  IEEE802.1X & MAC address authentication  
  Broadcast storm control,Backup for host datum
  SSH 2.0,SSL,Port isolation,ARP message speed limit
  User hierarchical management and password protection
DHCP DHCP Client, DHCP Snooping, DHCP Server, DHCP Relay
Management One-key recovery  
  Cable Diagnose,LLDP  
  Web Management (HTTPS)  
  NTP,System work log,Ping Test  
  CPU instant utilization status view  
  Console/AUX Modem/Telnet/SSH2.0 CLI  
  Download & Management on FTP, TFTP, Xmodem, SFTP,SNMP V1/V2C/V3
  ONV NMS - smart network management system platform(LLDP+SNMP)
System Category 5 Ethernet network cable  
  Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later;
  TCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in a network
s132_1