Home / Industrial switches / DARWIN-S129IB100002M

DARWIN-S129IB100002M

(0)
  Sale 20%
Sale 20%
Buy now in 1 click
L2+ managed industrial PoE fiber switch with 8*10/100/1000M RJ45 ports and 2*100/1000M SFP ports, Port 1-8 can support IEEE802.3af/at PoE. Support dual DC power supply input and DIN rail mounting.

OVERVIEW

 

DARWIN-S129IB100002M is a full Gigabit managed industrial PoE fiber switch independently developed by ONV. it has 8*10/100/1000M PoE ports and 2*100/1000M SFP fiber ports. Port 1-8 can support IEEE802.3af/at standard POE, single port POE power up to 30W.  As a POE power supply device, it can automatically detect and identify the electrical equipment that meets the standard and supply power through the cable. It can supply the POE terminal equipment, such as wireless AP, network camera, network telephone, industrial sensor and so on, to meet the demand for high density PoE power supply network environment. It is suitable for intelligent transportation, rail transit, electric power, mining, metallurgy and green energy. Industrial scenes such as construction set up a cost-effective and stable communication network.

The DARWIN-S129IB100002M has L2+ network management function, support IPV4 management, static route full line rate forwarding, security protection mechanism, ACL/QoS policy and VLAN, and is easy to manage and maintain. Support multiple network redundancy protocols STP/RSTP/MSTP(<50ms) to improve link backup and network reliability. When one-way network fails, communication can be quickly restored to ensure important Uninterrupted communication for applications. According to the actual application requirements, you can configure multiple application services such as PoE power management, port traffic control, VLAN division, and SNMP through the Web network management mode.

 

FEATURE

 

Gigabit access, SFP fiber port uplink

◇ Support Gigabit Ethernet port and Gigabit SFP port combination, which enables users to flexibly build networking to meet the needs of various scenarios.

◇ Support non-blocking wire-speed forwarding.

◇ Support full-duplex based on IEEE802.3x and half-duplex based on backpressure.

 

Powerful port lightning protection, ultra-wide voltage input

◇ Contact discharge 8KV, air discharge 15KV, port lightning protection common-mode 4KV, differential mode 2KV

◇ Industrial dual power input

◇ DC INPUT: 48V-57V

 

Intelligent PoE power supply

◇ 8*10/100/1000Base-T RJ45 ports, meeting the needs of security monitoring, teleconferencing system, wireless coverage, and other scenarios.

◇ IEEE802.3af/at PoE standard, without damaging non-PoE devices.

◇ Priority system for PoE port, it will supply power to the high priority level port first when the power budget is insufficient and avoid overwork of the device.

◇ PoE network management, realize PoE port power allocation, priority setting, port power status viewing, time scheduling, etc.

 

PoE network management and fast Ring function

◇ IEEE802.1Q VLAN, flexible VLAN division and QinQ configuration.

◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including EQU, SP, WRR & SP+WRR.

◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.

◇ IGMP V1/V2 and IGMP Snooping.

◇ STP/RSTP/MSTP.

◇ Static and dynamic aggregation.

 

Security

◇ 802.1X authentication.

◇ Port isolation,Storm control.

◇ IP-MAC-VLAN-Port binding.

 

Stable and reliable

◇ Low power consumption, aluminum shell. No fan.

◇ CCC, CE, FCC, RoHS.

◇ The user-friendly panel, it can show the device status through the LED indicator of PWR,SYS, Link, L/A, PoE.

 

One-stop remote control and management

◇ Web management, CLI command line (Console, Telnet), SNMP (V1/V2/V3).

◇ HTTPS, SSLV3, and SSHV1/V2.

◇ RMON, system log, LLDP, and port traffic statistics.

◇ CPU monitoring, memory monitoring, Ping test, and cable diagnose.

 

DIMENSION

S129_1
 
Interface Characteristics  
Fixed Port 8*10/100/1000Base-T PoE ports (Data/Power)
  2*100/1000Base-X uplink SFP slot ports (Data)
  1 * RS232 console port(115200,N,8,1)
  2 set of V+, V- redundant DC power interface (5 Pin Phoenix terminal)
Ethernet Port Port 1-8 support 10/100/1000Base-T,auto-sensing,Full/half duplex MDI/MDI-X self-adaption
Twisted Pair Transmission 10BASE-T: Cat3,4,5 UTP(≤100 meter)
  100BASE-TX: Cat5 or later UTP(≤100 meter)
  1000BASE-T: Cat5e or later UTP(≤100 meter)
SFP Slot Port Gigabit SFP optical fiber interface, default matching optical modules (optional order single-mode / multi-mode, single fiber / dual fiber optical module. LC)
Optical Cable/ Distance Multi-mode: 850nm/0 ~ 550M, single-mode: 1310nm/0 ~ 40KM, 1550nm/0 ~ 120KM.
Chip Parameter  
Network Management Type L2+
Network Protocol IEEE802.3 10BASE-T, IEEE802.3i 10Base-T, IEEE802.3u 100Base-TX
  IEEE802.3ab 1000Base-TX, IEEE802.3z 1000Base-X, IEEE802.3x
Forwarding Mode Store and Forward(Full Wire Speed)
Switching Capacity 128Gbps
Forwarding 14.88Mpps
Rate@64byte  
MAC 8K
Buffer Memory 4.1M
Jumbo Frame 10K
CPU(Hz) 500M
DRAM 1G
Flash 128M
LED Indicator Power: PWR (Green), System: SYS (Green), Network: Link (Yellow), Fiber port: L/A (Green), PoE: PoE (Green)
Reset Switch Yes. Press and hold the reset switch for 10 seconds and release it to restore factory settings
PoE & Power Supply  
PoE Port Port 1 to port 8
PoE Management PoE working status
  Delay start of power supply
  PoE output priority configuration
  Scheduling of PoE operation and time
  Total power limit of PoE power supply
  PoE output power allocation, off& af &at
Power Supply Pin 1/2 (+), 3/6 (-)
Max Power Per Port 30W, IEEE802.3af/at
Total Power/ Input Voltage 120W/48VDC
Power Consumption Standby<8W, Full load<120W
Input Voltage/ Interface 48-57VDC, 5P industrial phoenix terminal, support anti-reverse protection.
Power Supply No, optional 48V/120W or 48V/240W industrial power supply
Physical Parameter  
Operation TEMP / Humidity -40~+75°C, 5%~90% RH Non condensing
Storage TEMP / Humidity -40~+85°C, 5%~95% RH Non condensing
Dimension (L*W*H) 165*148*54mm
Net /Gross Weight <0.8kg / <1.2kg
Installation Desktop, DIN rail
Certification & Warranty  
Lightning Protection/ Protection Level Lightning protection: 6KV 8/20us; Protection level: IP40
  IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge
  IEC61000-4-3(RS):10V/m(80~1000MHz)
  IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV
  IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV
  IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz)
  IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s
  IEC61000-4-9(pulsed magnet field):1000A/m
  IEC61000-4-10(damped oscillation):30A/m  1MHz
  IEC61000-4-12/18(shockwave):CM 2.5kV,DM 1kV
  IEC61000-4-16(common-mode transmission):30V; 300V,1s
  FCC Part 15/CISPR22(EN55022):Class B
  IEC61000-6-2(Common Industrial Standard)
Mechanical Properties IEC60068-2-6 (anti vibration), IEC60068-2-27 (anti shock)
  IEC60068-2-32 (free fall)
Certification CCC,CE mark, commercial, CE/LVD EN60950, FCC Part 15 Class B; RoHS
Warranty 5 years, lifelong maintenance.
Network Management Features  
Interface IEEE802.3X (Full-duplex)
  Port temperature protection setting
  Port green Ethernet Energy-saving setting
  Broadcast storm control based on port speed
  The speed limit of the message flow in the access port.
  The minimum particle size is 64Kbps.
Layer 3 Features L2+ network management ,IPV4 management
  Static route, Default route @ 128 pcs, APR @ 1024 pcs
VLAN 4K VLAN based on port, IEEE802.1q
  VLAN based on the protocol, VLAN based on MAC
  QinQ configuration, Port configuration of Access, Trunk, Hybrid
Port Aggregation LACP, Static aggregation, Max 5 aggregation groups and 8 ports per group.
Spanning Tree STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s)
Industrial Ring Network Protocol 250 Ring at most, Max 250 devices per ring.
Multicast MLD Snooping v1/v2,Multicast VLAN
  IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out
Port Mirroring Bidirectional data mirroring based on port
QoS Flow-based Rate Limiting
  Flow-based Packet Filtering
  8*Output queues of each port
  802.1p/DSCP priority mapping
  Diff-Serv QoS,Priority Mark/Remark
  Queue Scheduling Algorithm (SP, WRR, SP+WRR)
ACL Port-based Issuing ACL,ACL based on port and VLAN
  L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc.
Security IP-MAC-VLAN-Port binding
  ARP inspection,Anti-DoS attack
  AAA & RADIUS,MAC learning limit
  Mac black holes,IP source protection
  IEEE802.1X & MAC address authentication
  Broadcast storm control,Backup for host datum
  SSH 2.0,SSL,Port isolation,ARP message speed limit
  User hierarchical management and password protection
DHCP DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay
Management One-key recovery
  Cable Diagnose,LLDP
  Web Management (HTTPS)
  NTP,System work log,Ping Test
  CPU instant utilization status view
  Console/AUX Modem/Telnet/SSH2.0 CLI
  Download & Management on FTP, TFTP, Xmodem, SFTP,SNMP V1/V2C/V3
  ONV NMS - smart network management system platform(LLDP+SNMP)
System Category 5 Ethernet network cable
  Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later;
  TCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in a network
S129