DARWIN-S009ID181602M
OVERVIEW
The DARWIN-S009ID181602M series is a full gigabit managed industrial PoE fiber switch independently developed. It has 16*10/100/1000Base-T RJ45 ports and 2*100/1000Base-X SFP fiber slot ports. Port 1-16 can support IEEE 802.3af/at standard PoE power supply. single port PoE power reaches 30W, and the maximum PoE output power is 250W(at-400W). As a PoE power supply device, it can automatically detect and recognize power-compliant devices that meet the standard and supply power through the network cable. It can supply power to POE terminal equipment such as wireless AP, webcam, VoIP, industrial sensor through the network cable, and meet the network environment that needs high-density PoE power supply. It is suitable for intelligent transportation, rail transit, power industry, mining, petroleum, Industrial scenes such as shipping, metallurgy, and green energy construction form a cost-effective, stable and reliable communication network.
The DARWIN-S009ID181602M has the L2+ full network management function, support IPV4/IPV6 management,static route full line rate forwarding,security protection mechanism,ACL/QoS policy and VLAN, and is easy to manage and maintain. Support multiple network redundancy protocols STP/RSTP/MSTP (<50ms) and (ITU-T G.8032) ERPS(<20ms) to improve link backup and network reliability. When one-way network fails, communication can be quickly restored to ensure important Uninterrupted communication for applications. According to the actual application requirements, you can configure multiple application services such as PoE power management, port traffic control, VLAN division, and SNMP through the Web network management mode.
FEATURE
Gigabit access, SFP fiber port uplink
◇ All series support “Gigabit Ethernet port and Gigabit SFP port”combination, which enables users to flexibly build networking to meet the needs of various scenarios.
◇ Support non-blocking wire-speed forwarding.
◇ Support full-duplex based on IEEE802.3x and half-duplex based on backpressure.
Intelligent PoE power supply
◇ 16*10/100/1000Base-T RJ45 ports, meeting the needs of security monitoring, teleconferencing system, wireless coverage, and other scenarios.
◇ IEEE 802.3af/at PoE standard, without damaging non-PoE devices.
◇ Priority system for PoE port, it will supply power to the high priority level port first when the power budget is insufficient and avoid overwork of the device.
◇ PoE network management, realize PoE port power allocation, priority setting, port power status viewing, time scheduling, etc.
Security
◇ 802.1X authentication.
◇ Port isolation,Storm control.
◇ IP-MAC-VLAN-Port binding.
Strong business processing capability
◇ IEEE802.1Q VLAN, flexible VLAN division,Voice VLAN and QinQ configuration.
◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including Equ, SP, WRR & SP+WRR.
◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.
◇ IGMP V1/V2 and IGMP Snooping.
◇ ERPS/STP/RSTP/MSTP.
◇ Static and dynamic aggregation.
Stable and reliable
◇ Low power consumption, No fan low noise design, aluminum shell.
◇ Self-developed power supply, high redundancy design, providing a long term and stable PoE power output.
◇ CCC,CE, FCC, RoHS.
◇ The user-friendly panel, it can show the device status through the LED indicator of PWR,SYS, Link, L/A,PoE.
Easy operation and maintenance management
◇ Web management, CLI command line (Console, Telnet), SNMP (V1/V2/V3).
◇ HTTPS, SSLV3, and SSHV1/V2.
◇ RMON, system log, LLDP, and port traffic statistics.
◇ CPU monitoring, memory monitoring, Ping test, and cable diagnose.
DIMENSION
Model | DARWIN-S009ID181602M | DARWIN-S009ID181602MW |
Interface | 16*10/100/1000Base-T PoE ports (Data/Power) | |
2*100/1000Base-X uplink SFP fiber slot ports (Data) | ||
1 * RS232 console port(115200,N,8,1) | ||
PoE Port | Port 1-16 | |
Network Protocol | IEEE802.3 10BASE-T; IEEE802.3i 10Base-T; | |
IEEE802.3u 100Base-TX; | ||
IEEE802.3ab 1000Base-T | ||
IEEE802.3z 1000Base-X | ||
IEEE802.3x | ||
PoE Standard | IEEE802.3af/at | |
Ethernet Port Feature | 10/100/1000Base-T,Auto-sensing,Full/half duplex MDI/MDI-X self-adaption | |
SFP Port | Gigabit SFP optical fiber interface, default matching optical modules (optional order single-mode / multi-mode, single fiber / dual fiber optical module. LC) | |
Forwarding Mode | Store and Forward(Full Wire Speed) | |
Switching Capacity | 256Gbps | |
Forwarding Rate@64byte | 26.78Mpps | |
MAC | 8K | |
Buffer Memory | 6M | |
Jumbo Frames | 9.6K | |
Twisted Pair Transmission | 10BASE-T: Cat3,4,5 UTP(≤100 meter) | |
100BASE-TX: Cat5 or later UTP(≤100 meter) | ||
1000BASE-T: Cat5e or later UTP(≤100 meter) | ||
Optical Cable | Multi mode: 850nm 0 ~ 550M,single mode: 1310nm 0 ~ 40KM, 1550nm 0 ~ 120KM. | |
Power Supply Pin | 1/2 (+), 3/6 (-) | |
Max / Average Power Per Port | 30W/15.4W | 30W/30W |
Total PWR / Input Voltage | 250W (AC100-240V) | 400W (AC100-240V) |
Power Consumption | Standby:<16W;Full load:<240W | Standby:<20W;Full load:<380W |
Power Supply | Built-in power supply, AC 100~240V 50-60Hz 4.1A | Built-in power supply, AC 100~240V 50-60Hz 5.0A |
Power Input Interface | Dual input power interface, AC power supply priority, | |
support anti-reverse protection, power-off automatic switching DC connection; 2 sets of DC12-48V input interface; | ||
LED Indicator | Power:PWR(yellow), system :SYS(yellow), network ;Link(yellow), POE: PoE (green), Rate:Speed:(green),Fiber port: L/A(green) | |
Reset Button | Support one key to restore factory settings | |
Operation TEMP / Humidity | -20~+55°C;5%~90% RH Non condensing | |
Storage TEMP / Humidity | -40~+75°C;5%~95% RH Non condensing | |
Dimension | 440*298*44.5mm | |
Net /Gross Weight | <4.2kg / <4.7kg | <4.4kg / <5.0kg |
Installation | Desktop, 19 inch 1U cabinet | |
Lightning protection / protection level | Lightning protection: 6KV 8/20us;Protection level: IP30 | |
IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge | ||
IEC61000-4-3(RS):10V/m(80~1000MHz) | ||
IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV | ||
IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV | ||
IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz) | ||
IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s | ||
IEC61000-4-9(pulsed magnet field):1000A/m | ||
IEC61000-4-10(damped oscillation):30A/m 1MHz | ||
IEC61000-4-12/18(shockwave):CM 2.5kV,DM 1kV | ||
IEC61000-4-16(common-mode transmission):30V; 300V,1s | ||
FCC Part 15/CISPR22(EN55022):Class A | ||
IEC61000-6-2(Common Industrial Standard) | ||
Mechanical Properties | IEC60068-2-6 (anti vibration),IEC60068-2-27 (anti shock),IEC60068-2-32 (free fall) | |
Certification | CCC;CE mark, commercial; CE/LVD EN60950;FCC Part 15 Class B;RoHS; | |
Network Management Features | ||
Interface | IEEE802.3X (Full-duplex) | |
Broadcast storm control based on port speed | ||
The speed limit of the message flow in the access port. The minimum particle size is 64Kbps. | ||
Port temperature protection setting | ||
Port green Ethernet Energy-saving setting | ||
PoE Management | Total power limit of PoE power supply | |
PoE output power allocation, off & af & at | ||
PoE output priority configuration | ||
PoE working status | ||
Delay start of power supply | ||
Scheduling of PoE operation and time | ||
Layer 3 Features | L2+ Network management | |
IPV4/IPV6 management | ||
L3 soft routing forwarding, | ||
Static route, Default route @ 128 pcs, APR @ 1024 pcs | ||
VLAN | 4K VLAN based on port, IEEE802.1q | |
VLAN based on the protocol | ||
VLAN based on MAC | ||
Voice VLAN, QinQ configuration | ||
Port configuration of Access, Trunk, Hybrid | ||
Port Aggregation | LACP, Static aggregation | |
Max 9 aggregation groups and 8 ports per group. | ||
Spanning Tree | STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s) | |
Industrial Ring Network Protocol | G.8032 (ERPS),Recovery time less than 20ms | |
255 Ring at most, Max 1024 devices per ring. | ||
Multicast | IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out | |
MLD Snooping v1/v2,Multicast VLAN | ||
Port Mirroring | Bidirectional data mirroring based on port | |
QoS | Diff-Serv QoS,Priority Mark/Remark | |
8*Output queues of each port | ||
802.1p/DSCP priority mapping | ||
Queue scheduling algorithm (SP, WRR, SP+WRR) | ||
Flow-based Packet Filtering | ||
Flow-based Redirection | ||
Flow-based Rate Limiting | ||
ACL | L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc. Port-based Issuing ACL. | |
ACL based on port and VLAN | ||
Security | User hierarchical management and password protection | |
SSH 2.0,SSL,Port isolation,ARP message speed limit | ||
Broadcast storm control,Backup for host datum | ||
IEEE802.1X & MAC address authentication | ||
Mac black holes,IP source protection | ||
AAA & RADIUS,MAC learning limit | ||
ARP inspection,Anti-DoS attack | ||
IP-MAC-VLAN-Port binding | ||
DHCP | DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay | |
Management | Console/AUX Modem/Telnet/SSH2.0 CLI,Web Management (HTTPS) | |
Download & Management on FTP, TFTP, Xmodem, SFTP,SNMP V1/V2C/V3 | ||
One-key recovery,NTP,System work log,Ping Test | ||
Cable Diagnose,LLDP,CPU instant utilization status view | ||
ONV NMS - Smart Network Management System Platform (LLDP+SNMP) | ||
System | Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later;Category 5 Ethernet network cable | |